[ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] [ 7 ] [ 8 ] [ 9 ] [ 10 ] [ 11 ] [ back ]
The independent outputs of the USRBIN scoring (unfortmatted output on unit 23, in the present example) from the different FLUKA runs must be summed together using the program usbsuw.f:
#!/bin/sh $FLUTIL/usbsuw <This program (usbsuw) may be modified by the user to insert possible calls to invoke (or prepare input for) graphic routines. In any case a formatted output is by default available (gasbr_sum.lis), where the user can find a table like the one of Fig. 1.
Figure 1: Part of the formatted output from the use of
usbsuw.fAs a conclusion, we report in Fig. 2 a plot obtained in ref.[1] using the described input.
Figure 2: Maximum absorbed dose per mA of beam lost as a function
of the distance from the end of the straight section
Giuseppe Battistoni; INFN, Milano
Alberto Fassò; SLAC, CaliforniaLast updated: 10th of October, 2008